p o w e r t r a n s f o r m e r chassis mount : toroidal medical series web: www.triadmagnetics.com phone 951 - 277 - 0757 fax 951 - 277 - 2757 460 harley knox blvd. perris, california 92571 publish date: june 19 , 2015 v pm 24 - 10420 description : the toroidal construction inherently reduce s stray fields , increase s efficiency and minimize s size compared to traditional ei transformers . the addition of a flux band further reduces the remaining stray fields. the shield b etween primary and secondary improves safety, reduces common mode signals and minimizes leakage current . built with a class f (155 ) insulation system . a 140 c self - resetting thermal switch is included in each p rimary. electrical specifications (@25c) 1. maximum power: 250 va 2. input voltages: 100, 120, 220, 240vac, 50/60hz 3. output voltages: 12 vac @ 20. 8 4 a or 24 vac ct @ 10.4 2 a 4. voltage regulation: 6.2 % typ from full load to no load 5. temperature rise: 5 5c typ 6. hipot: 4000vac, primary to secondary , primary & secondary to shield & mounting surface 7. efficiency: 93 % typ. @ full load agency file: ul: f ile e122529, ul 60601 - 1/(r) 2012 medical electrical equipment C part 1 ce: es 60601 - 1 (iec 60601 - 1:2005, mod) cul : c22.2 no. 60601 - 1:14, medical electrical equipment C part 1 cb certified. dimensions : inches (mm) *add 0.188 ( 3 ) to the height for mounting hardware weight: 2.5 kg mounting: transformer is provided with one metal mounting plate, two rubber pads, m6 x 65 mm bolt, nut, spring and flat washer. connections: transformer is provided with 12 (305mm) long, 0.5 (12 .7 mm) stripped and tinned, stranded ul 1 015 lead wire. primaries are 20 awg, second aries are 14 awg , and shield is 20awg . the grn/yel shield lead is typically grounded . do not lift transformer by leads! input options : 100vac: input to gray & blue, jumper white & brown, jumper blue & violet. 120vac: input to white & blue, jumper white & brown, jumper blue & violet. 220vac: input to gray & violet, jumper blue & brown 240vac: input to white and violet, jumper blue & brown output options : 120 vac: output from black & red, j umper black & orange, jumper red to yellow 240vac : output from black & yellow, jumper red & orange primary and secondary windings are designed to be connected in series or parallel. windings are not intended to be use d independently. rohs compliance: m eet s the requirements of 2011/65/eu, known as the rohs 2 initiative. * at printing, this document is considered uncontrolled. contact triad magnetics website for current version o.d. i.d. ht.* 4. 8 ( 123 ) 1 .8 ( 45 ) 2.4(60 ) rohs 2011/65/eu photo for illustration only rohs 2011/65/eu rubber pad rubber pad spring washer mounting metal plate nut od h flat washer bolt blu gry vio brn blk red org yel s c h e ma tic sec wht pri grn/yel
|